Thermodynamic Performance Analysis and Optimization of Domestic Refrigerator with Varying Refrigerant Charge and Capillary Tube Lengths
In this paper, thermodynamic performance analysis and optimization of a domestic refrigerator were
experimentally carried out by simultaneously varying the refrigerant charge (wr) and the capillary tube
length (L). Continuous running and cycling tests were performed on a domestic refrigerator under tropical
conditions using three refrigerants (R12, LPG and R600A) with different capillary...
Published at Energy Procedia
Pages 1-6
Published in 2016
S.O Oyedepo, R.O Fagbenle, T. O Babarinde , K. M Odunfa, R.O Leramo, P.O Babalola, O Kilanko, A.D Oyegbile,and Lawson-Jack D
BABALOLA Philip Olufemi » Dr. Engr. Babalola is a proven consulting engineer and have succeeded in turning many engineering ideas into reality all over the country, from design stage all through to project completion. He is teaching metallurgy, advanced engineering materials, internal combustion engines, fluid power systems, heat transfer, engineering law, engineering management, engineering entrepreneurship,... view full profile